A study on heat transport limitation for a perfluorocarbon heat pipe

PFC 히트파이프의 열전달 한계에 관한 연구

  • 강환국 (성균관대학교 기계기술연구소) ;
  • 김재진 (성균관대학교 대학) ;
  • 김철주 (성균관대학교 기계공학과)
  • Published : 1999.05.01

Abstract

A PFC(Perfluorocarbon) heat pipe has been used recently for cooling of GTO(gate turn off) thyristors or diodes in electric commuter trains. The present study was conducted to determine heat transport limitation of a PFC heat pipe which is one of the important parameters in heat pipes design. The variables such as tube diameter, fill charge ratio, internal surface structure and operating temperature were examined by way of experiment. Experimental data showed that the heat transport limitation of PFC heat pipe was considerably low and mostly dependent on tube diameter, with the value of 440~500W for d$o$/=22.23mm and 150~200W for d$o$=15.88mm. The other parameters had negligible effects, except for the case of small charge ratio less than 30%. Some correlations proposed by previous studies were in agreement with data from this study within 10~30%.

Keywords