Abstract
Recently, a method of measuring impulse response is widely used for a room acoustic evaluation instead of measuring reverberation time by white noise excitation. Comparing with the traditional reverberation time measurement, this method has many advantages such as good repeatability and the ability to extract various room acoustic parameters at one measurement. In this study, the author developed a measuring system that can extract mono-aural room acoustic parameters from an impulse response measured with MLS (Maximum Length Sequence) signal excitation. These room acoustic parameters include reverberation times(EDT, RT), speech intelligibilities(C50, C80, D, U50, U80, AI) and sound strength(G). This paper introduces the configuration of the developed measuring system, test results and discussions for the measurements at several rooms.
최근 들어 실내음향 특성의 측정과 평가를 위해 백색잡음을 이용한 잔향시간 측정법 대신에 임펄스응답을 이용한 측정법이 널리 이용되고 있다. 이 방법은 재현성이 우수하고 다양한 실내음향 특성치들을 한꺼번에 산출할 수 있어 전통적인 잔향시간 측정법에 비해 여러 가지 장점을 가지고 있다. 본 연구에서는 MLS(Maximum Length Sequence) 신호를 이용하여 실내에서의 임펄스 응답을 측정하고 이를 후처리(post-processing) 하여 잔향시간(EDT, RT), 명료도 지수(C50, C80, D, U50, U80, AI), 음의 크기 지수(G) 등, 주로 실의 음성음향 성능을 측정하는 시스템을 구축하였다. 본 연구에서는 측정시스템과 후처리 프로그램의 구성, 몇몇 실내공간에 대한 시험 측정의 결과 및 고찰 등에 대해 소개하고자 한다.