Abstract
Eight RC bridge plers have been made on a 1/3.4 scale model and have been tested in a quasi-static cyclic load so as to investigate their seismic performance. The ultimate objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete plers, which have been widely used for urban transportation facilities in Korea. Improtant test parameters are hoop ratio, axial load, load pattern, and etc. And noninear behaviors of test columns have been evaluated through their yield and ultimate strength, energy dissipation, ductility and load-deflection characteristics under quasi-static cyclic loads. From the quasi-static tests on 8 bridge piers, it is concluded that energy dissipation, ultimate strength and curvature for a given displacement factor ${\mu}={\Delta}/{\Delta}_y$ are higher for the seismically designed columns than for the nonseismically designed columns.
본 연구는 철도, 도시고속화도로 및 고속도로 교량의 교각으로 많이 이용디고 있는 철근콘크리트 기둥으 내진성능 평가에 관한 quasi-static 실험으로서 사용된 실험 변수는 축하중 내진설계유무에 따른 띠철근량 변위제어 하중형태 등을 채택하였다 RC 기둥시험체는 수원에 위치한 하갈교의 교각을 1/3.4의 축소모델로 하여 내진설계된 단면과 내진설계되지 않은 시험체를 각각 4개씩 총 8개를 제작하였으며 소성힌지구간에서 띠철근의 간격은 2.2cm 및 4.4cm 이다 실험변수에 따른 내진 및 비내진 시험체의 내진성능검토를 위하여 충진콘크리트 교각의 하중변위 이력특성 연성능력, 강도감소, 에너지 흡수능력, 등가점성계수 등을 실험적으로 분석조사하였다. '96년 개정된 도로교시방서의 RC기둥에 관한 내진설계기준은 AASHTO(1992)와 유사한 것으로서 중.약지진 지역으로 구분되는 국내의 실정에는 다소 과다설계로 판단된다. 실험결과 비내진설계된 콘크리트 교각도 어느 정도의 연성능력을 발휘한 것으로 조사되었으나 추가의 충분한 실험연구가 요구된다. 그러나 비내진설계교각도 적절한 내진보강방안을 강구한다면 우수한 내진성능을 발휘할수 있으리라판단된다.