Effects of Applied Load on the Vickers Microhardness in Pure Cu Specimen

시험하중의 변화가 순수한 Cu시편의 비커스 미소경도에 미치는 영향

  • 조영래 (고등기술연구원 플라즈마기술센터) ;
  • 이근호 (고등기술연구원 플라즈마기술센터)
  • Published : 1999.04.01

Abstract

Vickers microhardness for polished Cu specimen has been measured by conventional and new methods. The conventional microhardness was measured by observing the diagonal of indentation after the load was removed. Whereas, the new method for microhardness was obtained by measuring the penetration depth of indenter into the specimen under the load. As the applied load was increased, the microhardness obtained by new method was increased. When the applied load was in the range of 5mN to 80mN, the rate of elastic to total depth of indenter was about 6% and the calculated depth of rounded indenter was 0.07$\mu\textrm{m}$. The difference in microhardness measured by two different methods such as conventional and new methods can be explained in terms of the elastic deformation of specimen, the shape of practical indenter and pile up of material.

Keywords

References

  1. J. Mater. Res. v.7 no.613 G.M. Pharr;W.C. Oliver;F.R. Brotzen
  2. Thin Solid Films v.157 no.195 D.S. Rickerby;P.J. burnett
  3. J. Vac. Sci. Technol. v.A8 no.117 Feldman;F. Ordway;J. Burnstein
  4. J. Mater. Res. v.7 no.618 T.A. Laursen;J.C. Simo
  5. Phil. Mag. A v.48 no.593 J.B. Pethica;R. Hutchings;W.C. Oliver
  6. J. Vac. Sci. Technol. v.A3 no.2406 H.A. jehn;Uwe Kopacz;S. Hofmann
  7. Surface and Coating Technology v.75 no.849 D. Mueller;Y.R. Cho;E. Fromm
  8. Materialpruefung v.32 no.310 D. Dengel
  9. DEUTSCHE NORM
  10. Advanced Materials & Process v.8 no.23 G.D. Quinn
  11. PhD Thesis Y. R. Cho
  12. Annual Book of ASTM Standards v.3 no.342
  13. Journal of Tribology v.106 no.43 J.L. Loubet;J.M. Georges;O. Marchesin;G. Meille
  14. J. Mech. Phys. Solids v.5 no.125 L.E. Samuels;T.O. Muhlhearn