High Frequency Soft Switching Forward DC/DC Converter

고주파 소프트 스위칭 Forward DC/DC 컨버터

  • 김은수 (한국전기연구소 전력자원연구부) ;
  • 최해영 (한국전기연구소 위촉연구원, 부산대 산업대학원) ;
  • 조기연 (한국전기연구소 책임연구원) ;
  • 김윤호 (중앙대 공대 전기공학과 교수, 당 학회 부회장)
  • Published : 1999.02.01

Abstract

To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.

본 연구는 새로운 영전압, 영전류 스위칭 Forward 컨버터에 관한 것으로 종래의 하드 스위칭(Hard-Switching) Forward 컨버터에 있어서 Turn-off 및 Turn-off시 발생되는 스위칭 손실 및 출력 다이오드 역회복 특성에 따른 손실증가와 스위칭시 발생되는 기생진동을 Forward 컨버터에 있어서 1차측 주 스위칭소자 및 2차측 출력 정류다이오드와 병렬로 무손실 스너버를 적용함으로써 Forward 컨버터의 1차측 스위칭 소자의 Turn-off 및 Turn-on시 영전압, 영전류 스위칭을 이룰 수 있고, 출력 정류다이오드도 영전압, 영전류 스위칭 됨으로 다이오드의 역회복손실 및 기생 진동에 따른 EMI(Electro-Magnetic Interference)를 줄일 수 있는 무손실 스너버 적용 영전압, 영전류 스위칭 Forward 컨버터에 관한 것이다.

Keywords

References

  1. IEEE PE Analysis and Optemization of Nondissipative LC Turn-Off Snubber T. Ninomiya;T. Tanaka;K. Harada
  2. A New ZC-ZVS Forward Converter A. A. Pereira;E. A. A Coelho;V. J. Farias;L. C. de Freitas
  3. A New Boost Converter Using A Non-Dissipative Snubber J. A. C Pinto;A. A. Pereira;V. J. Farias;L. C. de Freitas
  4. Intelec'97 An Improved Soft Switching Forward DC/DC Converter Using Energy Recovery Snubber E.S. Kim;K.Y. Joe;Y.B. Byun;Y.H. Kim
  5. 일본전기학회 반도체전력변환방식조사전문위원회편 반도체전력변환회로