The Transactions of the Korean Institute of Electrical Engineers B (대한전기학회논문지:전기기기및에너지변환시스템부문B)
- Volume 48 Issue 11
- /
- Pages.587-596
- /
- 1999
- /
- 1229-2451(pISSN)
Characteristics on the Harmonic Sensitivity of an Induction Watthour Meter
유도형 적산전력량계의 고조파 민감도 특성
- Jang, Seok-Myeong (Dept.of Electronics Engineering, Engineering Collage, Chungnam National University) ;
- Lee, Seong-Ho ;
- Park, Yeong-Tae (Korea Reserch Institute of Standards and Science)
- Published : 1999.11.01
Abstract
The use of Switching elements in power systems causes the current or voltage to involve harmonic waves. Harmonics bring about registration errors of the equipment for measuring power. In case the induction watthour meter designed on sinusoidal source is used in the measurement of power with harmonics, the precise measurement of power has many problems because harmonics cause a decrease of power factor and vibration by the unstable driving force on the aluminum disc. In this paper, analysis and test results on the harmonic sensitivity of an induction watthour meter is reported when the input voltage and current with harmonics were supplied to single-phase watthour meter.