Characteristics of Transient Grounding Impedance under Surge Currents

서지전류에 대한 과도접지임피던스의 특성

  • 이덕희 (인하대 전기전자컴퓨터공학부) ;
  • 박종순 (인하대 전기공학과)
  • Published : 1999.11.01

Abstract

The transient characteristics of grounding systems play a major role in the protection of power equipments, electronic circuits and info-communication facilities against surges which arise from lightning or ground faults. Electronic devices are very weak against lightning surges injected from grounding systems and can be damaged. The malfunction and damage of electronic circuits bring about bad operation performances, a lot of economical losses, and etc. Therefore, in order to obtain the effective protection measure of electronic devices from overvoltages and lightning surges, the analysis of the transient grounding impedances in essential. One of this work is to examine the transient behaviors of grounding impedances under steplike currents for various grounding systems. And the other of this work is to evaluate the transient behaviors of a grid with rods under impulse currents and to investigate the effect of grounding lead wire. Transient grounding impedances of a grid with rods under impulse current waves have been measured as a parameter of the length of the grounding leads. Z-t, Z-i and V-i curves of transient grounding impedance under impulse current waveforms have been measured and analyzed. It was found that the grounding impedance gives the inductive, resistive and capacitive aspects under steplike current. Transient grounding impedance characteristics were very different with shapes, geometries of ground electrodes. Also, they were dependent on the waveform and magnitude of impulse current.

Keywords

References

  1. Proc. of '97 Japan-Korea Joint Symposium of Electrical Discharge & High Voltage Engineering Experimental Investigations on Transient Impedances of Some Grounding Systems B.H. Lee;J.S. Park;S.C. Lee
  2. IEEE Trans. v.PAS-102 no.9 Impulse Behavior of ground eletrodes C. Mazzetti
  3. '96 대한전기학회 하계학술대회 논문집 v.C no.PDH 14 펄스발생기에 의한 과도접지저항의 측정과 분석 이복희;박종순(外)
  4. 대한전기학회 방전 및 고전압 연구회 춘계학술대회 논문집 v.P-19 직각파 전류에 의한 여러 가지 접지극의 과도접지저항 특성 이복희;박종순(外)
  5. 전기학회 논문지 v.47 no.5 봉상접지극의 과도접지임피던스 특성 이복희;이승철;박종순
  6. 대한전기학회 추계학술대회 논문집 임펄스 전류에 대한 메쉬접지계의 과도임피던스 특성 이복희;박종순(外)
  7. Proc. IEE v.121 no.2 Dynamic Model of Impulse Characteristics of Concentrated Earth A.C. Liew;M. Darveniza
  8. IEEE Trans. v.PAS-100 no.11 Experimental Study of Transient Ground Impedances R. Kosztaluk
  9. 接地設計人門 高橋建蔘
  10. 雷とサ一ヅ 橋本信雄
  11. 日本電氣設備學會紙 接地抵抗のサ一ジ持性と對策 三谷 弘