Abstract
The dynamic resistance monitoring in primary circuit is one of the important issues. Because in-process and real time quality assurance of resistance spot weld is needed to increase the product reliability. In this study, new dynamic resistance detecting method is proposed as a practical manner of weld quality assurance using instantaneous current and voltage measured at the primary circuit. and also, various patterns of primary dynamic resistance curve are characterized with the macro photograph and the weldability lobe curve. It is found that the primary dynamic resistance patterns are basically similar to those of the secondary, but there is evident advantage such as no extra devices are needed to obtain the quality information and eventually real time feedback control will be possible.