정수처리용 최적분리막 선정을 위한 수질 비교

Comparison of Filtrate Quality to Select the Optimum Membrane for the Water Purification Process

  • 발행 : 1998.01.15

초록

This study was conducted to investigate how the pore sizes of MF and UF membranes affected the removal efficiencies. The experimental results were compared with those obtained from the existing sand filter to select the optimum membrane. Turbidity of the raw water was adjusted to 10, 30, 50, 100, and 200NTU. The removal efficiencies of the turbidity and SS were nearly 100% for all membranes applied. Not membrane differences in the removal efficiencies of dissolved organics were also found. Thus, MF membrane with pore size $0.1{\mu}m$ was selected to obtain satisfactory removal efficiencies of turbidity and bacteria. Permeable flux was also considered. The $0.1{\mu}m$ MF membrane system was operated in the treatment plant to compare the results with those obtained from the existing sand filter. Turbidity, SS, $KMnO_4$ consumption, and number of coliform were chosen to be compared. Because there were not much differencies in the quality of the treated water, the existing coagulation-sedimentation-filtration process might be replaced and upgraded by simpler membrane process.

키워드