The Control Performance of the Active Control System with Insufficient Number of Control Sources and Sensors for the Reduction of Duct Noise

고차모드 수보다 적은 수의 제어음원과 센서를 이용한 덕트 방사소음 제어시스템의 제어성능

  • 윤두병 (한국과학기술원 기계공학과 대학원) ;
  • 김양한 (한국과학기술원 기계공학) ;
  • 정균양 (현대중공업 선박해양연구) ;
  • 조대승 (부산대학교 조선해양공학과)
  • Published : 1998.12.01

Abstract

When the lateral dimensions of a duct is larger than or comparable to the wavelengths of Interest, higher order modes propagate in the duct. These modes will be radiated and produce noise. A number of sensors and actuators for control of radiating noise from the duct have to be incorporated with the number of modes which one wants to control. These considerations motivated the present study that considers a control system which has less microphones and control sources than required. In this work, by theoretical analysis, the control performance of such a kind of system is investigated in terms of sound-field variables and control system variables. The possible maximum and minimum value. mean and variance of residual acoustic potential energy are derived for the set of primary sound fields.

Keywords