This study has been performed to test the flowability and filling ability of high flowing concrete as well as distribution of aggregate and pore of core specimen, heat of hydration, compressive strength and core strength of concrete. In addition, the resistance to chloride ion penetration and chemical solutionof concrete was tested in order to evaluate the resistance to sea water of concrete and its application of high flowing concrete using blended low heat cement in the field of Seohae Grand Bridge. The properties of high flowing concrete with blended low heat cement were compared with ordinary 25-240-15 concrete using Type V cement. As the results of this study, the flowability and filling ability of high flowing concrete with blended low heat cement is satisfied without vibration. Though the cement content of high flowing concrete with blended low heat cement was 400kg/m$^2$, the rising temperature of it was relatively lower than that of the ordinary 25-240-15 concrete with Type V cement. Also, the compressive of high flowing concrete with blended low heat cement is similar to that of the ordinary 25-240-15 concrete with Type V cement.
본 연구는 해양 매스 콘크리트 구조물인 서해대교 사장교 주탑기초(L${\times}$D${\times}$H : 66${\times}$28${\times}$32~38.2)에 콘크리트 타설시 다짐작업을 생략할 수 있고, 수화열에 의한 온도균열 발생을 제어할 수 있는 콘크리트의 사용에 대하여 적극적으로 검토한 것으로서 혼합형 저발열 시멘트를 사용한 초유동 콘크리트와 현장에서 사용중인 5종 시멘트를 사용한 25-240-15 보통 콘크리트를 주탑 기초 일부분에 적용하여 유동성, 강도발현 성능, 재료분리 저항성, 수화열, 내해수성 등을 비교 평가한 것이다. 그 결과, 저발열시멘트를 사용한 초유동 콘크리트는 별도의 다짐 작업없이도 우수한 작업성과 자기 충전성, 재료분리 저항성을 나타냈으며, 5종시멘트를 사용한 25-240-15보통 콘크리트보다 단위시멘트량이 54kg/$m^2$ 정도 증가했음에도 불구하고 오히려 수화열은 $10^{\circ}C$이상 저감되어 온도균열 제어에 매우 효과적임을 확인할 수 잇었다. 또한 부재에서 채취한 코아의 압축강도는 5종시멘트를 사용한 25-240-15 보통 콘크리트와 동등한 강도 발현율을 나타내었다. 특히 해수중 염소이온의 침투에 대한 저항성을 평가하기 위해 실시한 촉진 염소이온침투 시험결과 통과전하량이 5종 보통 콘크리트보다 5배정도 낮게 나타났으며, 기타 화학물질에 대한 저항성은 비슷한 경향을 보였다. 따라서 저발열 시멘트를 사용한 초유동 콘크리트는 유동성개선에 의한 다짐 작업의 생략 효과와 더불어 수화열 저감 효과에 따른 온도균열제어 및 공기단축 등으로 주탑기초의 콘크리트에 매우 유리한 시멘트라고 판단되었다.