초록
In order to develop more rapid and reproducible analysis of biotin known as vitamin H, attempts were made to establish the condition for enzyme linked immunosorbent assay(ELISA) compared with traditional microbiological assay(MBA). Antibiotin and antiserum were obtained from the immunized rabbits injected with emulsion of biotin KLH conjugate and Freund's adjuvant. The antiserum showed cross reactivity on biocytin, a derivative of biotin, which is converted to biotin in intestine, at the rate of 177%(median inhibitory concentration(IC50)=12.58ppb), but not on other derivatives such as desthiobiotin, diaminobiotin and 2 imino biotin. Specific antibody for biotin was purified from the antiserum through protein A column and desalting column. The conditions of competitive direct ELISA (cdELISA) were established. Detection range of biotin concentration by cdELISA was 0.01∼300ng/ ml(ppb). In the spike test with milk, fruit flake and pine carrot juice, the correlation coefficient between two methods of MBA and ELISA was reliably consistent at the value of r=0.992. But detection of biotin by microbiological assay(MBA) was rather restricted in range and nonspecific. Detection range of biotin by MBA was 0.1∼0.5ng/ml(ppb). It showed cross reactivities on biocytin and desthiobiotin at the rate of 80.1% and 66.7%, respectively. In conclusion, ELISA revealed a significant improvement compared with MBA for the biotin detection in terms of sensitivity, detection range and cross reactivity. In addition, a variety of samples could be analyzed rapidly and conveniently at one time by using ELISA. These results strongly suggest that the ELISA is very promising for the practical application to detect biotin contents in a wide range of food stuffs.