Numerical simulation of turbulent air-flow in a closed engine room with heat source in a ship

열원이 있는 밀폐된 선박 기관실에서의 난류기류에 관한 수치적 연구

  • Published : 1998.02.01

Abstract

Ventilation of the marine engine room is very important for the health of the workers as well as the nomal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-.epsilon. model was carried out. In the present study, the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with downword angle depresses recirculation flow, causing a strong steam in the wider space of the room. Ventilation and removal of the released heat are promoted with this pattern. There is a possibility of local extreme heating at the upper surface of engine when supply and exhaust ports of air are in bilateral symmetry. The effect of the increase of exhaust port area on ventilation decreases as the number of supply port increases.

Keywords

References

  1. Energy Conservation in Heating, Cooling and Ventilating Buildings Prediction of Buoyancy Influenced Flow in Ventilated Inductrial Hall Larsson, M.
  2. TSME interrational journal, Series 2 v.2 Movement of Small practies caused by an Air Flow in a Chamber Suzuki, H.;Hasegawa, E.;Matsufuji, H.
  3. computer Methods in Applied Mechanics and Engineering The numerical computation of Turbulent Flows Launder, B. E.;Spalding, D. B.
  4. ASHRAE Trans v.33 Three-Dimensional Numerical Simulation of Turbulence Air-flow in a ventilated Room by means of a Two-Equation Model Murakami, S.;Kato. S;Sayama, S.
  5. 대한 기계 학회 논문집 v.3 no.3 실내 공간에서 부력이 있는 가스의 확산 거동에 관한 수치해석적 연구 장문석;이창식;우재성
  6. 전산유체 역학의 기초와 응용 최형돈