The Effect of the Diameter and Anastomotic Angle on the Compliance and the Stress Distribution of the End-to-side Anastomosis.

직경 및 문합각도가 단측 문합의 컴플라이언스 및 응력분포에 미치는 영향

  • Published : 1998.04.01

Abstract

Von Mises stress and compliance distribution was evaluated using a finite element analysis on the end-to-side anastomosis of an artery with length of 20-24mm, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 10mm, inner diameter of 2mm, thickness of 0.2mm when the anastomotic angle was taken from 30$^{\circ}$~90$^{\circ}$ in every 10$^{\circ}$ and the diameter ratio from 0.1-1 in every 0.1. The inner pressure of 1330 dyne/$\textrm{mm}^2$ was applied inside the 2 conduits. It was found that the compliance whose magnitude is larger on the acute angle anastomotic side than on the abtuse angle side became larger as the anastomotic angle became smaller and the diameter ratio larger and that the equivalent stress on the acute angle anastomotic side was larger than that on the abtuse angle side and became larger as the anastomotic angle and the diameter ratio became larger.

동맥과 PTFE 재료로 된 대체혈관이 혈관폐색이 생긴 부위를 우회하기 위하여 단측문합이 되었을 때 문합각의 변화에 의한 영향을 살펴보기 위하여 두 혈관의 직경비를 0.5로 고정하고 문합각을 30$^{\circ}$에서 90$^{\circ}$까지 $10^{\circ}$간격으로 변화시켜 컴플라이언스와 응력의 분포형태를 살펴보고 또한 직경비의 영향도 살펴보기 위하여 문합각을 45$^{\circ}$로 고정하고 직경비를 0.1에서 1까지 0.1간격으로 변화시켜 컴플라이언스와 응력의 변화를 살펴보았다. 단측문합비에 사용된 모델은 20-24mm, 내경 4mm, 두께 0.5mm의 동맥과 길이 10mm, 내경 2mm, 두께 0.2mm의 PTFE 대체혈관이 사용되었으며 문합각이 작아지거나 직경비가 커질수록 예각 문합부의 컴플라이언스가 점점 더 커진다는 것을 알았다.

Keywords

References

  1. ASME Journal of Biomechanical Engineering v.115 A Numerical Simulation of Flow in Two-Dimensional End-to-side Anasomosis Model D. A. Steinman;B. Vinh;C. R. Ethier;M. Ojha
  2. Arch. Surg. v.119 Postsurgical changes in arterial compliance J.E. Hasson;J. Megerman;W. A. Abbott
  3. J. Vasc. surg. v.2 Increased compliance near vascular anastomosis J. E. Hasson;J. Megerman;W. A. Abbott
  4. J. Vasc. surg. v.3 Suture technique and para-anastomotic compliance J. E. Hasson;J. Megerman;W. M. Abbott
  5. J. Cordiovasc. Surg. v.21 Compliance: a continuing problem with vascular grafts C. E. Kinley;A. E. Marble
  6. mechanical properties in graft design. In Graft materials in vascular The role of surgery W. M. Abbott;J. Bouchier-Hayes;Dardik H.(ed.)
  7. Med. & Biologial Eng. & Computing Finite-element analysis of arterial anastomoses with vein, Dacron and PTFE grafts K. B. Chandran;D. Gao;G. J. Han;H. Baraniewski;J. D. Corson
  8. J. Biomed. Engr. v.12 Numerical 3-D Simulation of Pulsatile Wall Shear Stress in an Arterial T-Bifurcation Model K. Perktold;R. Peter
  9. J. Biomech. v.23 A Numerical Analysis of Steady Flow in a Three-Dimensional Model of the Carotid Artery Bifurcation C. M. Rindt;A. A. Van Steenhoven