A Evaluation of Corrosion Resistance on the Thermal Sprayed Coating Tube and Cladded Tube of the Open Rack Vaporizer

용사코팅튜브와 클래드튜브 기화기에 대한 내식성 평가

  • 백종현 (한국가스공사 연구개발원) ;
  • 이재호 (홍익대학교 금속재료공학과) ;
  • 김용석 (홍익대학교 금속재료공학과) ;
  • 신동혁 (한양대학교 금속공학과) ;
  • 김우식 (한국가스공사 연구개발원)
  • Published : 1998.12.01

Abstract

Due to excellent corrosion resistance, in particular against sea water, Al-2wt.$\%$Zn alloys have been used as the sacrifice anode material for tube of the ORV. Al-2wt.$\%$Zn alloys thermal-sprayed coating, however, were spalled on the lower part of ORV due to the lack of bonding strength between base material and coating layer and the dropping energy of sea water, To overcome the problems of the thermal spray coating, we developed the cladded tube manufacturing process by coextrusion of the clad and base metal. The corrosion resistance of cladded tube was improved by two times at least, compared with that of the present thermal spray coated vaporizer tubes.

Al-2wt.$\%$Zn 합금은 특히 해수에 대한 내식성이 우수하여 기화기 튜브의 회생양극재료로 사용되고 있다. 그러나 Al-2wt.$\%$Zn 용사코팅재는 모재금속과 코팅층사이의 결합강도부족, 해수의 낙하에너지에 의해 코팅층은 박리 된다. 이러한 용사코팅충의 문제점을 해결하고자 클래드재와 모재금속을 동시압출법을 통하여 클래드튜브 제조공정을 개발하였다. 클래드튜브의 내식성은 용사코팅튜브에 비하여 최소 2배 이상 향상되었다.

Keywords