Journal of radiological science and technology (대한방사선기술학회지:방사선기술과학)
- Volume 20 Issue 2
- /
- Pages.49-55
- /
- 1997
- /
- 2288-3509(pISSN)
- /
- 2384-1168(eISSN)
A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan
부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구
- Jeon, Sung-Oh (Dept, of Diagnostic Radiology, Inje university Pusan Paik hospital) ;
- Cho, Young-Ha (Graduate School of Public Health, Inje University)
- Published : 1997.12.20
Abstract
This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at