직접냉각에 의한 수소액화장치의 성능실험

Performance experiment of a hydrogen liquefaction equipment by direct cooling

  • 백종훈 (한국과학기술연구원, 공조.환경제어연구팀) ;
  • 강병하 (한국과학기술연구원, 공조.환경제어연구팀) ;
  • 장호명 (홍익대학교 기계공학과)
  • 발행 : 1997.08.01

초록

A hydrogen liquefaction equipment by direct cooling has been designed and built at KIST. Cool-down characteristics and liquefaction performance of the equipment have been investigated. The hydrogen liquefaction equipment consists of a GM refrigerator, a liquefaction velssel, a radiation shield and a cryostat. It is found that the hydrogen starts to be liquefied in the liquefaction vessel after 40~50 minutes of cool-down from the gas state of 270K. The effect of natural convection phenomena of charged gas in liquefaction vessel on the cool-down characteristics is evaluated by comparing with those in vacuum of liquefaction vessel. It is seen that the cool-down time of a liquefaction vessel is substantially increased in vacuum environment of liquefaction vessel. The experiments have been performed for 1~5 atm of hydrogen pressure to investigate the influence of hydrogen pressure on the liquefaction rate and figure of merit(FOM). It is found that both liquefaction rate and FOM are increased as the charged hydrogen pressure is increased.

키워드