Design of the Fittest Eddy Current Probe for the Fin Tubes

Fin 튜브의 와전류탐상을 위한 최적 탐촉자의 설계

  • Kim, Y.J. (Korea Research Institute of Standards and Science) ;
  • Lee, S.K. (Korea Research Institute of Standards and Science) ;
  • Ahn, B.Y. (Korea Research Institute of Standards and Science) ;
  • Chung, M.H. (Korea Electric Power Research Institute)
  • Published : 1997.08.05

Abstract

The eddy current probe was designed for the test of fin tubes that have uneven outer and inner surfaces to enhance the efficiency of heat emission. Because of the surface roughness of the fin tube, it needs much care to detect flaws in the tube employing eddy current test(ECT). We made ECT probes with different coil lengths and performed eddy current test using these probes for artificially flawed specimens. By the fast Fourier transform and digital filtering, signals from these probes were processed to characterize frequency spectra. From the analysis of eddy current signals and their frequency spectra, we concluded that, for the effective testing of the tubes with the fins of 1mm pitch, 4mm coil length gave the highest S/N ratio.

열 전달 효율을 증가시키기 위하여 튜브의 내 외면에 울퉁불퉁한 지느러미가 부착된 fin 튜브의 와전류탐상을 위하여 와전류 탐촉자를 설계하고 시험하였다. Fin 튜브는 거친 표면으로 인하여 와전류탐상으로 결함을 찾기 위해서는 많은 주의가 필요하다. 본 연구에서는 규격이 다른 와전류 탐촉자를 제작하고 인공 결함 시험편에 대하여 탐상을 실시하였다. 실험한 와전류탐상 신호에 대하여 FFT를 통하여 주파수 스펙트럼을 구하였고 디지털 필터링의 신호 처리를 하여 신호의 주파수 특성을 고찰하였다. 신호와 주파수 특성을 분석한 결과, 본 연구 대상 시험편에서와 같이 1mm 피치의 fin 튜브의 경우 4mm의 코일 거리를 지닌 탐촉자가 가장 좋은 S/N비를 나타내었다.

Keywords