The Characteristics of the Ozonation of phenol wastewater by the variation of pH using the continuous PCR and BCR

연속식 PCR과 BCR에서 pH 변화에 따른 페놀 폐수의 오존처리특성에 관한 연구

  • 안재동 (건국대학교 화학공학과) ;
  • 김민수 (건국대학교 화학공학과) ;
  • 김용대 (서강전문대학 환경위생과) ;
  • 최석규 (경주전문대학 환경공업과)
  • Published : 1997.03.01

Abstract

This study was performed to estimate the ozonation characteristics of phenol wastewater with increasing pH in the continuous packed column reactor (PCR) and the bubble column reactor (BCR). Among various influencing factors that affect phenol on decomposition through the ozonation, pH was chosen as reaction parameter. Upon increasing pH from 3 to 9, the phenol removal efficiency in PCR was improved approximately by 17% while in BCR approximately by 19.2%. The improvements in the phenol removal efficiency by increasing pH caused the enhancements in ozone utilization efficiency reaching almost 100% in PCR at pH 9. In conclusions, ozone has latent power for phenol wastewater treatment, and the performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.

Keywords