Effects of Domestic Wastewater Treatment used Biofilm-Electrode Reactor(BER)

生物膜 電極反應機를 이용한 廚房廢水 처리 효과

  • Noh, Hyun-Woong (Chungnam Institute of Health & Environment) ;
  • Yoon, Oh-Sub (Dept. of environmental engineering, National Taejeon University of Technology)
  • Published : 1997.03.01

Abstract

This study was aimed to estimate removal efficiency(%) of BER(Biofilm-Electrode Reactor) and A.S(Activated Sludge) treatments. When were analyzed COD$_{Cr}$, NH$_3$-N and T-P by current density and reaction time, the results were as follows : 1) In BER treatment, the removal efficiency of COD$_{Cr}$ in domestic wastewater was 79-86% when current density was 2.39 mA/dm$2$(15mA)-3.98 mA/dm$^2$(25mA) and reaction time was 48 hr. 2) Removal efficiency of NH$_3$-N was 71-73% when current density was 2.39-3.98 mA/dm$^2$ and reaction time 48 hr. 3) When the reaction time was 48 hr removal efficiency(%) of BER treatment for COD$_{Cr}$, NH$_3$-N and T-P were more excellent than A.S. treatment. And then we prospect that was because activated microorganism colonies attached in biofilm on surface of electrode pannel. Therefore, In order to derive BER treatment efficiency(%) should establish optimum conditions of pH, temp., reaction time, current density and biochemical and electrochemical states.

Keywords