Abstract
Base-isolation of a primary structure generally decrete the seismic response of its own and the secondary structure. It may cause an adverse effect on the seismic response of secondary system when the system is submerged and subject to a considerable hydrodynamic effect. In this paper, it is shown how, and how much, the base isolation of the primary structure can affect the secondary system response in extreme cases through dynamic analysis of a simplified coupled model for a submerged secondary system and a base-isolated primary structure. As an aseismatic design approach to reduce the response of the submerged system, optimization of the fluid gap, which controls the hydrodynamic mass effect, is performed. As an alternative approach in case where the control of fluid gap is unrealistic, application of base isolation to the submerged system is suggested. Effectiveness of various combinations of the primary base and secondary base isolations are compared.
건물내 동적계가 수중에 있고 유체동적효과가 클 경우, 건물을 지진절연하면 일반적인 경향과는 달리 계의 지진응답이 오히려 증가될 수 있다. 본 논문에서는 건물내 수조에 잠긴 계에 대하여 단순화된 복합모델의 동적해석을 통하여 건물의 지진절연이 건물내 수중계의 지진응답에 어떻게 그리고, 최대로 얼마나 영향을 주는지를 보인다. 이 때 응답을 줄이기 위한 내진설계방안으로서 유체질량효과를 조절하는 유체간극의 최적화를 수행하여 그 효과를 살펴보았고, 간극조절이 곤란한 경우의 대안으로서 지진절연된 건물내 수중계를 다시 지진절연하는 방안을 제안하였으며 적절한 이중절연방식의 조합에 대한 효율을 비교하였다.