Radiation Oncology Journal
- Volume 15 Issue 3
- /
- Pages.243-249
- /
- 1997
- /
- 2234-1900(pISSN)
- /
- 2234-3156(eISSN)
The Study of Normal Tissue Complication Probability(NTCP) for Radiation Pneumonitis by Effective Volume Method
유효체적 방법과 임상분석을 통한 방사선에 의한 정상 폐조직의 부작용 확률에 관한 연구
- Ahn Seung Do (Department of Radiation Oncology, Asan Medical Center, College of Medicine, University of Ulsan) ;
- Choi Eun Kyung (Department of Radiation Oncology, Asan Medical Center, College of Medicine, University of Ulsan) ;
- Yi Byong Yong (Department of Radiation Oncology, Asan Medical Center, College of Medicine, University of Ulsan) ;
- Chang Hyesook (Department of Radiation Oncology, Asan Medical Center, College of Medicine, University of Ulsan)
- 안승도 (울산대학교 의과대학 서울중앙병원, 방사선종양학과교실) ;
- 최은경 (울산대학교 의과대학 서울중앙병원, 방사선종양학과교실) ;
- 이병용 (울산대학교 의과대학 서울중앙병원, 방사선종양학과교실) ;
- 장혜숙 (울산대학교 의과대학 서울중앙병원, 방사선종양학과교실)
- Published : 1997.09.01
Abstract
Purpose : In radiation therapy, NTCF is very importart indicator of selecting the optimal treatment plan. In our study, we tried to find out usefullness of NTCP in lung cancer by comparng the incidence of radiation pneumonitis with NTCP. Materials and Methods : From August 1993 to December 1994, thirty six patients with locally advanced non=small cell lung cancer were treated by concurrent chemoradiation therapy. Total dose of radiation therapy was 6480cGy (120cGy, bid) and chemotherapeutlc agents were mitomycin C. vinblastion, cisplatin (2 cycles, 4 weeks interval). We evaluated the development of raniation pneumonitis by CT scan, chest x-rar and clinical symptoms. We used grading system of South Western Oncology Group (SWOG) for radiation pneumanitis. Dose Volume Histograms (DVH) were analyzed for ipsilateral and whole lung, Non uniform DVH was translated to uniform DVH by effective volume method. With these data, we calculated NTCP for ipsilateral and whole lung. Finally we compared the clinical results to NTCP. Results : Eight of thrity six patients developed radiation pneumonitis. Of these 8 patients , 6 had grade I severity and 2 had grade II. The average NTCP value cf the patients who showed radiation pneumonitis was significantly higher than that uf the patients without pneumonitis
목적 : 방사선에 대한 정상 폐조직의 부작용에 관한 확률은 폐암의 방사선 치료에 있어서 중요한 지표가 됨에도 닥구하호 잘 알려져 있지 안다. 더구나 표적 부위와는 달리 정상 폐조직의 방사선량 분포는 매우 불균일하므로, 대표 선량값을 찾아 내는 것조차 어렵다 본 연구에서는 Dose Volume Histogram(DVH)과 유효체적방법(Effective Volume Method)을 통하여 정상 폐조직의 선량을 정량화하고 정상 폐조직 부작용 확률(Normal Tlssue Complication Probability, NTCP)을 구하여 임상결과와 비교하므로서 이 방법이 치료 결과를 예측할 수 있는 주요 지표로서 가능할 수 있는지에 대하여 살펴 보고자 하였다. 대상 및 방법 : 1993년 8월부터 1994년 12월까지 비세포성 폐암으로 방사선과 복합항암약물요법을 병행하여 치료받은 환자 중에서 36명을 무작위 추출하여, DVH 분석을 통한 정상 폐조직의 NTCP를 구하였다. 36명의 환자는 Mitomycin C, Vlnblastlne, Clsplatln을 사용한 2회의 복합항암 약물요법과 동시에 다분할 방사선추료(120cBy11x, bld)를 6480c0y까지 병행 치료하였다. 각 환자의 치료전 CT scan을 사용하여 우측폐, 좌측폐 그리고 전체폐 각각의 DVH를 구하였다. Kutcher등의 Effective Volume Method로 Nonuniform Histogram을 Uniform Histogram으로 변환시켰고,