매몰재의 혼수비가 치관 보철물 변연의 적합성에 미치는 영향에 관한 연구

A Study on the Marginal Fit of Dental Prosthesis According to the W/P Ratio of Investment

  • 황경숙 (신흥전문대학 치기공과)
  • Hwang, Kyung-Sook (Dept. of Dental Laboratory Technology Shin Heung Junior College)
  • 발행 : 1996.07.01

초록

This test is verifying for influence of W/P ratio of investment upon dental prosthesis Firstly we made 40 MOD die and divide 4 groups, each group take 0.2 different w/p ratio grade such as 0.35, 0.37, 0.39 and 0.41. The method of data analysis applied were by ANOVA, Tukey test and Mann-Whiney and Kruskal Wallis test. The finding of this study were as follows : 1. The 0.37 w/p ratio group showed most accurte margin due to $15.8{\mu}m$ gap between margin and die which keep up with manufacture's instruction and 0.35 w/p ratio group was followed as second accuracy group o 새 $48.3{\mu}m$ gap between margin and die, 0.39 w/p ratio group showed $101{\mu}m$ gap and 0.41 w/p ratio group showed $129.8{\mu}m$ gap. 2. As to the relationship of the margin accuracy between 4 different grade of w/p ratio groups, each group was statistically significant(P<0.01). Also the all groups were statistically significant except between 0.35 and 0.37 groups between 0.39 and 0.41 groups, and between 0.35 and 0.39 groups. 3. A consequence of Mann-Whitney & Kruskal-Wallis test for marginal accuracy between 4 different grade of w/p ratio was statistically significant as same as above ANOVA test result. Also Tukey test for verifying similarity from each group showed same as above.

키워드