흉부X선촬영(胸部X線撮影)에 있어서 피폭선량(被曝線量)의 저감(低減)에 관(關)한 연구(硏究)

A Study on the Chest Radiography for Reducing Exposure Dose

  • 이만구 (원광보건전문대학 방사선과) ;
  • 윤한식 (원광보건전문대학 방사선과) ;
  • 이종석 (원광보건전문대학 방사선과) ;
  • 이선숙 (동아X선기계 방사선기술연구소) ;
  • 임태랑 (일본 화학요법연구소부속병원 방사선실) ;
  • 석전유치 (일본 화학요법연구소부속병원 방사선실) ;
  • 전전미향 (일본 화학요법연구소부속병원 방사선실) ;
  • 앵정달야 (일본 화학요법연구소부속병원 방사선실)
  • Lee, Man-Koo (Dept. of Radiotechnology, Wonkwang Public Health College) ;
  • Yoon, Han-Sik (Dept. of Radiotechnology, Wonkwang Public Health College) ;
  • Lee, Jong-Seok (Dept. of Radiotechnology, Wonkwang Public Health College) ;
  • Lee, Sun-Sook (Institute of Radiological Technology, Dong A X-ray Co., Ltd.) ;
  • Hayashi, Taro (Dept. of Radiotechnology, The Chemotherapy Institute Hospital) ;
  • Ishida, Yuji (Dept. of Radiotechnology, The Chemotherapy Institute Hospital) ;
  • Maeda, Mika (Dept. of Radiotechnology, The Chemotherapy Institute Hospital) ;
  • Sakurai, Tatsuya (Dept. of Radiotechnology, The Chemotherapy Institute Hospital)
  • 발행 : 1996.06.30

초록

We have been used super sensitive screen/film system which is thought to be the limit of sensitivity, however, we think this method is not satisfactory. As a general radiographic rule, reduction of exposure is inconsistent with improvement of image quality, but it is necessary to challenge this rule to get better method. We tried air gap method for minimal diffuse lung shadow which is difficult to find out by our routine method. As a result, air gap method with super sensitive screen/film system(SRO 1000/TMH) showed lower exposure dose, 50% of our routine system(SRO 750/SRH with grid), and better image quality for pulmonary pattern in the lower lung field.

키워드