사진 주사(走査)를 이용한 치과용 모형재의 정확도에 관한 연구

A STUDY ON THE ACCURACY OF DENTAL CAST AND DIE MATERIALS USING PHOTO-SCANNING

  • 양성욱 (단국대학교 치과대학 보철학교실) ;
  • 임주환 (단국대학교 치과대학 보철학교실) ;
  • 조인호 (단국대학교 치과대학 보철학교실)
  • Yang, Seong-Wook (Dept. of prosthodontics, College of Dentistry, Dankook university) ;
  • Lim, Ju-Hwan (Dept. of prosthodontics, College of Dentistry, Dankook university) ;
  • Cho, In-Ho (Dept. of prosthodontics, College of Dentistry, Dankook university)
  • 발행 : 1996.11.01

초록

Dental cast and die materials are essential material using in almost dental prsthodontic procedure and it's most important requirement is accuracy for reqorducing the oral anatomical structures. In this study, 5 abutments A, B, C, D, E were fabricated on the metal master model to simulate the arch form and specimens were poured with 4 cast materials. Inter-abutment distances, A-B, A-C, A-D, A-E, B-C, B-D were calculated using the photo-scanning and the deviations from the metal master model were also evaluated. The results were as follows; 1. The distance between A-B, A-C, A-D, A-E, B-C, B-D of the abutments A, B, C, D, E of each cast material was calculated. And after comparing the deviations between the metal master model. $Fujirock^{(R)}$ showed the lowest value with $0.20{\pm}0.22mm$, and the deviation increased in the order of $Suprastone^{(R)}$, Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. 2. In each calculation area, the difference in measurements between cast material and metal master model showed singificant difference between A-B and Cross arch measure-ments of A-D, B-D, A-E(p<0.05). 3. The difference in measurements between cast material and metal master model in the A-B area showed $Fujirock^{(R)}$ to be the lowest with $0.05{\pm}0.04$mm and increased in the order of Die $Keen^{(R)}$, $Suprastone^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and $Suprastone^{(R)}$, Epoxy $Die^{(R)}$ (p<0.05). 4. The difference in measurements between cast material and metal master model in the B-C area showed $Fujirock^{(R)}$ to bo the lowest with $0.17{\pm}0.11$mm and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Die $Keen^{(R)}$, Epoxy $Die^{(R)}$(p<0.05). 5. The difference in measurements between cast material and metal master model in the B-D area showed $Fujirock^{(R)}$ to bo the lowest with $0.13{\pm}0.07$mm, Epoxy $Dies^{(R)}$and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fuji-rock^{(R)}$ and Die Keen(p<0.05). 6. In this experiment, Epoxy $Dies^{(R)}$ showed mean contraction in every calculation area. And when reconstruction cross arch restorations it is thought that distortion should be considered in every cast material.

키워드