A SPECTROPHOTOMETRIC STUDY ON DISCOLORATION OF RESTORATIVE COMPOSITE RESINS IN COFFEE AND ARTIFICIAL SALIVA

분광광도계를 이용한 커피와 인공타액에서의 수복용 복합레진의 변색에 대한 연구

  • Eom, Seung-Hee (Department of Conservative Dentistry, College of Dentistry, Seoul National University) ;
  • Cho, Hyo-Sun (Department of Conservative Dentistry, College of Dentistry, Seoul National University) ;
  • Lee, Chung-Sik (Department of Conservative Dentistry, College of Dentistry, Seoul National University)
  • 엄승희 (서울대학교 치과대학 치과보존학교실) ;
  • 조효선 (서울대학교 치과대학 치과보존학교실) ;
  • 이정식 (서울대학교 치과대학 치과보존학교실)
  • Published : 1996.10.31

Abstract

The purpose of this study was to investigate by spectrophotometry the changes in color parameters of composite resins after exposure to distilled water, filtered coffee, and artificial saliva. Five kinds of fine particle composite resin in experiment 1, and six kinds of composite resin in experiment 2 were used. In experiment 1, each group of composite resin was stored in distilled water at $4^{\circ}C$, $50^{\circ}C$, and filtered coffee solution at $4^{\circ}C$, $50^{\circ}C$. And then each specimen was measured by spectrophotometer. Measurements were repeated in 1 hour, 2 hours, 4 hours, 8 hours, 16 hours, 24 hours, and 48 hours. In experiment 2, all specimens of each brand were stored in distilled water at $37^{\circ}C$, artificial saliva not contained mucin at $37^{\circ}C$, and artificial saliva contained mucin at $37^{\circ}C$. All specimens of each brand were measured by spectrophotormeter in 1 week, 2 weeks, 4 weeks, 8 weeks, and up to 12 weeks. The results were as follows : 1. In cold coffee, five of fine particle composite resins showed ${\Delta}E{^*}_{ab}$ values less than 2. However, in hot coffee ${\Delta}E{^*}_{ab}$ values of Amelogen Universal and Prisma TPH were higher than those of Conquest Crystal, ${\AE}$litefil and Z100. 2. Z100 and ${\AE}$litefil had better cleansibility of extrinsic coffee staining than Amelogen Universal, Conquest Crystal and Prisma TPH. 3. In distilled water and artificial saliva not contained mucin, five of fine particle composite resin showed ${\Delta}E{^*}_{ab}$ values less than 2 up to 12 weeks. However, Silux Plus showed higher than ${\Delta}E{^*}_{ab}$ values of fine particle composite resin. 4. As an immersion solution for discoloration experiment, artificial saliva not contained mucin showed similar appearance as distilled water. However, artificial saliva contained mucin had different appearance from the others. 5. In artificial saliva contained mucin, ${\AE}$litefil, Prisma TPH and Z100 showed ${\Delta}E{^*}_{ab}$ values less than 1 up to 12 weeks. However, Silux Plus, Amelogen Universal and Conquest Crystal showed ${\Delta}E{^*}_{ab}$ values more than 1 up to 12 weeks. But, Conquest Crystal showed different characteristics of chromacity difference value(less chromatic) and lightness difference value(lighter) from Silux Plus and Amelogen Universal.

Keywords

Acknowledgement

Supported by : 서울대학교 병원