Thermal Losses Due to Non-ideal Gas Behavior of Helium in VM Heat Pumps

헬륨의 비이상기체 거동에 따른 VM열펌프의 손실

  • 백종훈 (홍익대학교 기계공학과) ;
  • 장호명 (홍익대학교 기계공학과)
  • Published : 1996.05.01

Abstract

A cycle analysis is performed to investigate how the non-ideal gas behavior of helium reduces the heating capacity of VM heat pumps. Since the operating pressures of VM heat pumps are as high as 1 to 20 MPa, the compressibility factor of helium becomes clearly greater than 1 and the non-ideal behavior always represents a thermal loss in heating. To calculate the amount of the losses, an adiabatic cycle analysis is performed with the real properties of helium and the net enthaply flows through the two regenerators are numerically obtained. It is shown that the non-ideal gas losses could be as much as 8% in the heating capacity when the operating pressures are greater than 10MPa. The effects of the operating temperatures and the dead volumes on the loss are presented.

Keywords