A Study of Hydration Characteristics on Soluble Silicate to Develop Fire Protective Coating

방화피복재 개발을 위한 용해성 규산염의 수화특성에 관한 연구

  • 김정훈 (독일 Wuppertal 대학교 대학원) ;
  • 이내우 (부산공업대학교 안전공학과)
  • Published : 1996.03.01

Abstract

In order to investigate the effects on intumescence to fire protective coatings, the characteristics of solubility, hygroscopic nature and X-ray diffration results on soluble silicate were determined. Solubility is depended on the mutual action of each silicate. In the result of hygroscopic characteristics by water absorption under several kinds of relative humidity, lithium silicate is more stable than sodium and potassium silicate over moistures. Eventhough free water is evaporated over $100^{\circ}C$ , physically adsorption water and ionic water are eliminated about $200^{\circ}C$, but evolution of structural water is expected to be emitted between 400~$600^{\circ}C$ range. Those are considered to be contributed intumescence on soluble silicate.

Keywords