DOI QR코드

DOI QR Code

Effects of Reinforcing Method Influnced to the Shear Strength of Vertical and Horizontal Joints in Precast Concrete Large Panel Structures -Focused on the Vertical Joints and Slab-Slab Type Horizontal Joints-

대형판조립식 구조 수직.수평접합부의 전단강도에 미치는 보강방법의 영향-수직접합부 및 슬래브-슬래브 수평접합부를 중심으로-

  • 정란 (단국대학교 건축공학과) ;
  • 박현수 (신흥전문대 건축설계과) ;
  • 조승호 (단국대학교 건축공학과)
  • Published : 1996.08.01

Abstract

A proposal of the basic fbrm on the design of joint parts that can increase the shear strength by the useful joint shapes of each member is intended. The vertical joint parameters are the number of' shear key and a variety of' reinfbrcement details and the horizontal joint paramctcrs arc t,hc number of shear key and the direction of' shear f'orcc. 10 PC panel vortical joint arid 12 PC panel horizontal joint specimens were tested to investigate the effects of these parameters. Test results show that : 1. The ductility of the test specimen that has the horizontal reinforcing steels is larger than that does not have. 2. The maximum resisting force of round bar specimen is similar to that of strand wire specimen under the condition of fixed horizontal displacement.

PC판넬 조립식 구조의 수직.수평접합부의 유용한 접합형태에 따라 접합부 전단내력을 상승시킬 수 있는 접합부 설계의 기본 형태를 제시하는데 연구의 목적이 있다. 시험체는 수직접합부의 경우 전단키의 개수 및 보강철물의 종류에 변수를 주고 수평접합부의 경우에는 전단키의 갯수 및 가력방향에 변수를 주어 총 22개의 시험체를 제작하여 실험하였다. 결론적으로 수직접합부의 경우, 수평보강철물이 있는 시험체는 기존의 다른 실험결과와 마찬가지로 수평보강철물이 없는 시험체에 비하여 연성이 크게 나타났다. EH한 와이어로프와 원형철근 두 종류의 보강철물을 사용하여 실험한 결과 와이어 로프를 사용한 시험체는 원형철근을 사용한 시험체와 최대내력 및 전단강성 등 전체적인 구조거동이 거의 비슷하게 나타났다.

Keywords