DOI QR코드

DOI QR Code

An Experimental Study for Crack Prevention of Floor Mortar

바닥용 모르타르의 균열방지를 위한 실험적 연구

  • 정재동 (대구대학교 건축공학과,) ;
  • 최응규 (삼성물산(주)건설부문) ;
  • 김진근 (한국과학기술원 토목공학과) ;
  • 이칠성 (한국과학기술원 토목공학과) ;
  • 이상순 (한국과학기술원 토목공학과)
  • Published : 1996.06.01

Abstract

Recently, the mortar crack on floor is very serious in construction field, e.g. the crack due to plastic shrinkage and the crack due to drying shrinkage. To prevent this kind of crack, optimum mix proportions not only satisfying the required workability but also minimizing the unit water content were selected. And the expansion admixtures were used to compensate shrmkage of mortar. The water /cement ratio used in construction field is about 64% by the investigation. Even if the water /cement ratio of mortar is reduced, floor mortar is still able to have the required workability by the appropriate use of the fine aggregate with high fineness mo'dulus and superplastizer. The equations hetween mortar flow and water /cement ratio, sand /cement ratio, fineness modulus of fine aggregate were proposed in this study. And the proposed equation may provide available mix proportions of floor mortar.

최근 건설 현장에서 소성수축과 건조수축으로 인한 바닥용 모르타르의 균열은 매우 심가하다. 이러한 바닥용 모르타르의 균열을 방지하기 위하여 필요한 작업성을 유지하면서 단위수량을 최소화하는 최적배합의 선정과 팽창제를 사용하여 수축을 보상하는 방법에 대하여 연구하였다. 현장조사에 의하면 현장에서 사용중인 바닥용 모르타르의 물 시멘트는 약 64%인 것으로 나타났다.그리고 바닥용 모르타르의 물 시멘트를 줄이더라도 조립율이 큰 잔골재를 사용하고 고성능감수제를 적정량만큼 첨가하면 필요한 작업성을 유지할 수 있는 것으로 나타났다. 또한 이 연구에서는 모르타르의 플로우와 물 시멘트비, 잔골재시멘트비, 잔골재의 조립율과의 관계식을 제안하였으며, 제시된 식은 바닥용 모르타르의 배합설계에 유용하게 활용될 것으로 판단된다.