Abstract
The stress patterns of vertical stiffener of plate girder bridge were examined by existing data of actual measurement stress for steel bridges and the structural details of vertical stiffener of plate girder bridge having seeked rationalization and abbreviation were investigated by 1/2 bridge model. As the results, the out-of-plane stress occur in the upper parts of vertical stiffner and fatigue cracks by the action of alternative stress is apt to occur in web plate of lower parts vertical stiffener. Also, the gap between lower parts of vertical stiffner and lower flange of plate girder bridge seeking rationalization and abbreviation is effective to adopt 100mm.