Purpose : This study was performed for adequate irradiating tumor area when 6 MV linear accerelator photon was used to treat the head and neck tumor. The skin surface dose and maximum build-up region was measured by using a spoiler which was located between skin surface and collimator. Methods : A spoiler was made of tissue equivalent material and the skin surface dose and maximum build-up region was measured varing with field size, thickness of spoiler and interval between skin and collimator. The results of skin surface dose and maximum build-up dose was represented as a build-up ratio and it was compared with dose distribution by using a bolus. Results : The skin surface dose was increased with appling spoiler and decreased by distance of the skin-spoiler separation. The maxium build-up region was 1.5 cm below the skin surface and it was markedly decreased near the skin surface. By using a 1.0-cm thickness spoiler, Dmax moved to 5, 10.2, 12.3 13.9 and 14.8 mm from the skin surface by separation of the spoiler from the skin 0, 5, 10, 15. 20 cm, respectively. Conclusion : The skin surface dose was increased and maximum build-up region was moved to the surface by using a spoiler. Therefore spoiler was useful in treating by high energy photon in the head and neck tumor.

목적 : 6 MV x-선의 선형가속기를 이용하여 두경부종양환자를 치료시에 피부표면의 종양에 균일한 선량을 부여하기 위하여 조직등가물질로 산란판을 제작하여 산란판의 두께와 위치에 따라 조직의 표면선량과 최대선량지 점을 측정하였다. 방법 : 조직등가물질인 폴리스틸렌으로 산란판을 제작하여 가속기의 콜리메터와 피부사이에 부착하여 조사면, 산란판의 두께 및 피부와의 간격에 따라 피부표면 선량과 최대선량지점을 측정하여 측정결과는 최대선량 대 표면선량비(BUR-1)로 표시하였으며 불균등 표면보상에 사용하는 조직등가 볼러스에 의한 선량분포변화를 측정하여 산란판과 비교하였다. 결과 : 6 MV x-선 선형가속기와 피부사이에 산란판을 설치하여 피부선량이 증가되었으며 산란판의 위치에 따라 피부선량이 변화되었고 최대선량지점은 피부표면쪽으로 이동하였다. 최대 선량지점은 피부하 1.5 cm 깊이에서 최대선량이 투여되고 피부쪽으로 선량이 급속히 감소되어 1cm 두께의 산란판을 사용한 경우 피부간의 거리가 0, 5, 10, 15, 20 cm로 증가하였을때 최대선량지점은 피부표면으로 부터 5, 10.2, 12.3, 13.9, 14.8 mm로 증가되었다. 결론 : 6 MV x-선을 이용하여 두경부종양을 치료할 경우 산란판을 이용하여 이차산란전자를 피부표면 앞에서 발생시킴으로써 피부의 선량이 증가되어 최대선량지점은 피부표면으로 이동 시킴으로써 종양부위에 균일한 선량을 부여시킬 수 있었다.

Keywords