Abstract

One of the important factor in drug stuffs to a patient is to inject exact amount with stable flow rates. Since improper injection amount and flow rates would cause bad effect to recovery of a patient, the detecting sensors with high sensitivity is required for an injection pump systems' performance improvement. In this study, the three sensors, piezo film sensor, photo transistor and photo array, were compared to find best one for an injection pump monitoring system. Using suggested data processing technique and photo array sensors, we could minimize the effect of interference, disturbance, illumination, and sensitivity change caused by sensor's position. According to the experiments, the photo array showed the higher reliance than any other the three types of sensors.

수액을 장시간 환자에게 주입할 때 적절한 주입량, 주입률을 조절하는 것이 중요하다. 부적절한 주입량은 환자의 회복에 좋지 않은 영향을 끼칠 수 있으므로 주입량을 감지하는 센서의 신뢰도는 인퓨전 펌프 시스템에 많은 영향을 미친다. 본 연구에서는 인퓨전 펌프 시스템에 사용될 3가지 센서의 성능을 검토하였다. 피에조 필름, 광트렌지스터 및 광 다이오드 어레이의 3가지 센서가 비교되었으며 제안하는 신호 처리 기법과 광 다이오드 어레이를 사용한 기법을 이용하여 간섭과 진동 조도변화 센서의 위치에 따른 감도 변화등의 영향을 줄일 수 있었다. 실험 결과 광 다이오드 어레이가 다른 센서들에 비하여 높은 신지도를 보여 주었다.

Keywords