공기중 수은 농도의 측정방법에 대한 비교평가연구

A Comparative Evaluation of Sampling Methods for Airbone Mercury Concentration

  • 박주영 (고려대학교 환경학과 연구소) ;
  • 김광종 (고려대학교 환경학과 연구소) ;
  • 백남원 (서울대학교 보건대학원 산업보건학교실)
  • 발행 : 1995.11.10

초록

This study was performed to evaluate methods for determination of airbone mercury in industrial environments. Three methods, such as Hopcalite method, passive monitoring method and Jerome method were evaluated at two (2) fluorescent lamp manufacturing Plants in Korea during a period from May 24 to May 31, 1994 and the result are as follows: 1. The average were concentrations of airbone mercury were $26{\mu}g/m^3$ by Hopcalite method, $25{\mu}g/m^3$ by passive monitoring method, and $38{\mu}g/m^3$ by the Jerome method, respectively, which were below the permissible exposure limit of $50{\mu}g/m^3$ established by both the Korean Ministry of Labor and ACGIH. However, 12 out of 49 cases(24.4%) in plant A and 2 out of 31 cases(6.5%) in plant B were in excess of the standard. 2. The relationship between the results by Hopcalite method and the passive monitoring method was significant(r=0.892). 3. The variation among three results by eath of three methods were different by process. The highest variation was determined at quality control process("process b") which invoved in large variation of concentrations. 4. When short term high concentrations were produced, the Hopcalite method was more efficient then the passive method.

키워드

과제정보

연구 과제 주관 기관 : 산업보건연구소