Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients

갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가

  • Lim, Sang-Moo (Department of Nuclear Medicine, Korea Cancer Center Hospital) ;
  • Woo, Kwang-Sun (Department of Nuclear Medicine, Korea Cancer Center Hospital) ;
  • Chung, Wee-Sup (Department of Nuclear Medicine, Korea Cancer Center Hospital) ;
  • Hong, Sang-Woon (Department of Nuclear Medicine, Korea Cancer Center Hospital) ;
  • Kim, Jang-Hee (Laboratory of Radiation Safety and Control) ;
  • Kim, Ki-Sup (Laboratory of Radiation Safety and Control)
  • Published : 1995.03.31

Abstract

Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administered radiopharmaceuticals. With the biological distribution data and the physical properties of the radionuclide we can estimate the absorbed dose by the MIRD schema. For the thyroid cancer patients received $^{131}I$ therapy, the absorbed dose to the bone marrow is the limiting factor to the administered dose, and the duration of admission is deter-mined by the retained activity in the whole body. To monitor the whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity curve of the whole body, total body residence time was obtained. From the ICRP publication 53, the residence times of the source organs, such as kidney, urinary bladder content and stomach, were used to calculate the absorbed doses of the target organs, such as stomach, red marrow, bladder wall and remaineder total body. In 8 thyroid cancer patients with 175 mci of $^{131}I$ administered orally, the mean absorbed dose in the bladder wall was 375.1, in the stomach 285.1, red marrow 25.4 and total body 22.4 rad respectively. For the monitoring of the large administered activity, this method seemed to be quite useful.

방사성 핵종의 체내 투여 또는 체내 오염에 의한 내부피폭 흡수선량 측정을 위하여 개발된 MIRD 씨스템을 이용하여 175mCi $^{131}I$ 치료를 받는 8명의 분화된 갑상선암의 주변림프절 전이 환자에서 전신, 위, 신장, 방광 및 골수 등의 흡수선랑을 측정하였다. 전리함 검출기와 자료저장 장치가 부착된 Eberline Smart 200 씨스템을 이용하여 전신 $^{131}I$의 시간 방사능 곡선을 얻었고, 선형 회귀분석을 하여 곡선하면적을 구한 값을 투여 방사능량(Ao)으로 나누어 체류시간($\tau$)으로 하였다. MIRDose2의 S값을 이용하여 전신흡수선량을 구하였으며 ICRP publication 53의 표준인 신장, 방광, 위의 체류시간을 이용하여, 이들 장기의 흡수선량을 구하였다. 전신 및 골수의 흡수선량은 22.4 및 25.4rad로 ICRP 최대허용선량보다 훨씬 낮았으며, 방광에 375.1, 위에 285.1rad로 심각한 증상을 초래할 정도의 선량은 아니었다. 분화된 갑상선암의 폐 및 뼈전이 환자에서 200mCi 이상 투여방사능량을 증가시킬 경우 이 방법으로 전신 및 골수 등의 흡수 선량을 평가하여 안전성을 확인할 수 있을 것으로 생각된다.

Keywords