Nuclear Engineering and Technology
- Volume 27 Issue 2
- /
- Pages.203-215
- /
- 1995
- /
- 1738-5733(pISSN)
- /
- 2234-358X(eISSN)
Small Break LOCA Analysis for RCP Trip Strategy for YGN 3&4 Emergency Procedure Guidelines
영광3, 4호기 비상운전지침용 원자로냉각재펌프 정지전략을 위한 소형냉각재상실사고 분석
- Seo, Jong-Tae (Korea Atomic Energy Research Institute) ;
- Bae, Kyoo-Hwan (Korea Atomic Energy Research Institute)
- Published : 1995.04.01
Abstract
A continued operation of RCPs during a certain small break LOCA may increase unnecessary inventory loss from the RCS causing a severe core uncovery which might lead to a fuel failure. After TMI-2 accident, the CEOG developed RCP trip strategy called “Trip-Two/Leave-Two” (T2/L2) in response to NRC requests and incorporated it in the generic EPG for CE plants. The T2/L2 RCP trip strategy consists of tripping the first two RCPs on low RCS pressure and then tripping the remaining two RCPs if a LOCA has occurred. This analysis determines the RCP trip setpoint and demonstrates the safe operational aspects of RCP trip strategy during a small break LOCA for YGN 3&4. The trip setpoint of the first too RCPs for YGN 3&4 is calculated to be 1775 psia in pressurizer pressure based on the limiting small break LOCA with 0.15 ft
소형냉각재 상실사고시 원자로냉각재펌프( RCP )의 지속적인 운전은 원자로냉각재의 불필요한 누출을 초래하여 심각한 노심노출 및 이에따른 핵연료 손상을 야기시킬 수 있다. TMI 사고 후 미국 NRC의 요구에 따라 CE형 발전소 사용자 단체에서는 “T2/L2”라는 RCP 트립전략을 개발하여 CE형 발전소에 적용 가능토록 일반비상운전지침서에 반영하였다. 상기 T2/L2 RCP 트립전략은 사고후 원자로 냉각재 계통의 압력이 감소하여 RCP 트립설정치에 도달하면 처음 두대의 RCP를 우선 정지시키고, 사고가 LOCA임이 확인되면 나머지 두대의 RCP를 정지시키는 방식을 채택하고 있다. 본 논문에서는 영광3, 4호기의 RCP 트립설정치를 분석, 선정하고 T2/L2 전략의 안전운전양상을 입증하였다 분석결과, 최악의 파단크기로 밝혀진 0.15 ft
Keywords