Numerical Analysis of Cathodic Protection Effect by Sacrificial Anode Attached to Condenser of Power Plant

희생양극법에 의한 발전소 복수기의 음극방식효과에 대한 수치해석

  • 김장순 (전력연구원 금속재료연구팀) ;
  • 배병홍 (전력연구원 금속재료연구팀) ;
  • 김의현 (전력연구원 금속재료연구팀) ;
  • 이충근 (전력연구원 금속재료연구팀) ;
  • 김종영 (전력연구원 금속재료연구팀)
  • Published : 1995.10.01

Abstract

The effect of cathodic protection by the sacrificial anode attached to condenser waterbox of power plant was investigated using numerical analysis. The condenser is consisted of various materials. So in case of no protection, the serious galvanic corrosion between waterbox and tubesheet was observed. If sacrificial anodes were attached to the wall of waterbox or the area corroded galvanically, the large protection effect was showed. To demonstrate the validity of numerical analysis results, model test was executed. The numerical solution was consistent with the experimental vague well.

희생양극법에 의한 발전소 복수기 수실의 음극방식 효과를 수치해석을 이용하여 알아보았다. 복수기는 해수설비중의 하나로 여러 재질로 구성되어 있는데 방식을 하지 않은 경우 수실과 tubesheet와의 갈바닉 부식이 심하게 발생되며, 수실벽과 갈바닉 부식이 심하게 일어나는 부위에 희생양극을 부탁하면 많은 방식효과가 있음을 알 수 있었다. 수치해석 결과의 타당성 검토로서 model test를 행한 결과 수치해석 결과와 실험치가 잘 일치하였다

Keywords

References

  1. Electrochim. Acta. v.9 J.A. Klingert;S. Lynn;C.W. Tobias
  2. Corrosion v.1 G. Prentice;R.A. Holser;V.J. Farozic;R.B. Pond,Jr;K.L. Cramblitt
  3. 火力原子力發展 v.11 S. Ingaki;S. Wado;N. Kikuna;S. Shiode;T. Sasamoro;M. Miyazaki;Y. Nishino
  4. 火力原子力發展 v.4 S. Inagaki;N. Kikuna;T. Satou;Y. Nishino;M. Miyazaki
  5. Computer Modeling in Corrosion R.A. Adey;s.M. Niku
  6. Computer Modeling in Corrosion K.R. Trethewey;J.S. Keenan
  7. Electrical Engineering Applications v.7 Topics in Boundary Element Research C.A. Brebbia
  8. 中間報告書 Studies on the Current and Potential Distributions of Cathodic Protection Systems 韓國電氣硏究所
  9. 復水器工學 handbook 川邊允志;荒木道郞;藤井哲;靑水潮