Abstract
The purpose of this study is to spread beam plastic hinging zone of the high-strength($f'_c=700kg/cm^2$) reinforced concrete beam-column joints away from the column face by vertically anchored intermediate reinforcements. The newly proposed intermediate reinforcements which are vertically anchored by interlinking each intermediate rebars are tested to insure the ductile behavior of R /C beam-column joins. Main variable is the shape of intermediate reinforcements. From the test results, the newly proposed intermediate rebar detail can move arid expand the beam plastic hinging zone about 1.Od from column face and can delay the strength decay of the high-strength R /C beam-column joint. Also energy dissipation capacity of specimen IV-1.OD10 which is reinforced by vertically anchored intermediate rebars about 1.0d is 1.6 times as high as the specimen CM-STAN which is designed by ACI318-89.
본 논문은 고강도 콘크리트($f'_c=700kg/cm^2$)를 사용한 보_기둥 접합부의 소성힌지 확산을 위하여 중간철근을 수직으로 앵커한 수직앵커형 중간철근으로 보 단부를 보강함으로써 보_기둥 접합부에 발생하는 소성힌지를 보 내측으로 1.0d 만큼 확산시키고자 하는 것이다. 실험의 주 변수로는 중간철근의 유물 및 앵커여부로 설정하여 중간철근의 보강형태에 따른 부재의 역학적 거동을 규명하도록 하였다. 실험결과로부터 보 단부의 1.0d부분을 수직앵커형 중간철근으로 보강하면 소성힌지를 1.0d 부분으로 확산할 수 있었으며, 에너지 분산능력도 ACI318-89에 따라 설계한 관례적인 실험체에 비하여 약 1.6배정도 향상되었다.