자기 베어링의 성능한계를 고려한 작동특성 연구

Performance Study of Magnetic Bearing Considering the Performance Limit

  • 장인배 (서울대학교, 터보.동력기계연구센터) ;
  • 한동철 (서울대학교, 터보.동력기계연구센터)
  • 발행 : 1995.03.01

초록

In this study, we investigated the operational limit of magnetic bearing-rotor system due to the maximum force limit and slew rjate limit of the electromagnetic actuator as a function of the time dependent control characteristics. The feedback gain of the controller varies the current of the electromagnet coil with the motion of the rotor. The distorsion of magnetic force due to the slew rate limit is not occurred jup to 30, 000 rpm in the magnetic bearing that we have a close relation with the rotational speed and vibration level of the rotor and the proportional gain of the controller. Therefore the maximum force limit determines the maximum allowable orbit radius of the magnetic bearing-rotor system. The maximum allowable vibration levels are exponentially decreased according to the increment of rotational speed and proportional gain of the controller.

키워드

참고문헌

  1. Trans. ASME. J. of Tribology v.113 Meassured and Predicted Force and Stiffness Characteristics of Industrial Magnetic Bearing Imlach,J.;Blair,B.J.;Allaire,P.E.
  2. Trans. ASME.J.of Tribology v.114 Determination of Forces in a Magnetic Bearing Actuator Knight,J.D.;Zia,Z.;McCaul,E.;Hacker,H. Jr.
  3. Report No. UVA/643092/MAE93/450, Univ. of Verginia Implicit Flux Feedback Control for Magnetic Bearing Keith,F.J.;Williams,R.D.;Maslen,E.H.
  4. Trans. ASME. J. of Tribology v.111 Practical Limits to the Performance of Magnetic Bearing Maslen,E.;Hermann,P.;Scott,M.;Humphris,R.R.
  5. Electromagnetics Kraus,J.D.
  6. Korea-U. S. Vibration Seminar A Performance of Analog PID Controlled Magnetic Bearing of a Rotor System Han,D.C.;Chang,I.B.
  7. 최신 FET 규격표
  8. 공학박사학위논문, 서울대학교 캐패시턴스형 센서가 내장된 자기 베어링의 작동성능 향상에 관한 연구 장인배