Abstract
Korea-America tungsten treaty is not only Earnning Us Dollar but also it was turnning point of tunnelling technology development such as a burn cut. Because 10th of specialist worked at Sangdong mine under treaty. The first of all, Experimental blasting pattern for single free face carried out. As a result it has brought the burden and $charge/m^3$ and also space distance. After the center holes are blasted. Remain of the works was the implementation of bench cut against the openning to make the full sectional are required. $Ca=\frac{A}{SW}$ where as A =ndi=m activated area S = Peripheral length of Charged room Ca = Rock Coefficient di=Holes diameter Later in 1980, The Oynaite Explosive is Replaced into Emulsion & Milli-Second Delay Electric Cap. Seqential Blasting machine were Applied in the Site. The Subway Tunnelling have been worked so Carefully for Vibration and Noise to near Shopping and housing area. We carried out Empirical formula to solve city Envoirement pollution as follow For Granite: $V=KW^{0.57}D^{-1.75}$ For Granite : $V=KW^{0.5}D^{-1.5}$ V=PPV(cm/sec) K=Coefficency D=Distance(m) W=Amount of power/delay(kg)
본 논문은 '95년 10월 27일 경주 Kolon Hotel에서 제25차 한일 기술사 공동 Symposium에서 발표된 내용이다.