A Study On the Accuracy Analysis of 3-Dimensional Position using Digital Image
수치 영상을 활용한 3차원 위치 정확도 해석
- Published : 1995.12.31
Abstract
This study aims to apply digital photogrammetric methods on the close range photogrammetry. To get a three dimensional position with digital photogrammetric method, scanning, image matching, and bundle adjustment are performed. Comparing the three dimensional position computed by digital photogrammetric methods with ground survey values, the errors can be detected. Analyzing the errors, it is possible to present a new digital photogrammetric method for the close range photogrammetry. Image matching method used in this study is area-based pixel unit and subpixel unit method. As a result of the study, three dimensional position error is 3.32mm and the error in the single coordinate axis direction is 0.76mm in pixel unit and in subpixel unit, respective error is 3.98mm and 0.73mm.
본 연구에서는 근거리 사진측량에 수치사진측량기법을 적용하여 3차원 위치를 결정하였다. 이를 위해 근거리 사진측량으로부터 취득한 사진을 스캐너에 의해 수치영상으로 변환시키고, 영역적 영상정합기법으로 정합점을 탐색하여 사진의 외부표정요소를 결정한 후 기준점들의 3차원 위치값을 계산하였다. 이 값을 최초의 기준점 측량값과 비교하여 정확도를 분석함으로서 수치사진측량기법에서 적용할 수 있는 영상정합기법에 대해 연구하였다. 영상정합은 영역적 영상정합방법에 의한 정합점 추출방법을 채택하였으며, 영상소 단위까지의 영상정합기법과 부영상소 단위까지의 영상정합 실험을 실시하여 그 결과를 비교 분석하였다. 본 연구의 결과 영상소단위의 정합에서는 3.32mm의 3차원 위치오차를 얻을 수 있었으며, 단일 축 방향으로 0.76mm의 오차로 위치를 결정할 수 있었다. 부영상소 단위의 정합에서는 각각 3.98mm와 0.73mm의 오차로 위치를 결정할 수 있었다.