Applied Chemistry for Engineering (공업화학)
- Volume 5 Issue 1
- /
- Pages.44-53
- /
- 1994
- /
- 1225-0112(pISSN)
- /
- 2288-4505(eISSN)
A Study on Iron Electrode of Ni/Fe Battery(I) -High Utilization of Iron Electrode-
니켈/철 축전지의 철전극에 관한 연구(I) -철전극의 고이용률화-
- Kim, Un-Suk (Div. Chem Eng., KIST) ;
- Cho, Won-Il (Div. Chem Eng., KIST) ;
- Cho, Byung-Won (Div. Chem Eng., KIST) ;
- Yun, Kyung-Suk (Div. Chem Eng., KIST) ;
- Shin, Chee-Burm (Dept. of Chem Eng., College of Eng., Ajou Univ.)
- 김운석 (한국과학기술연구원 화공연구부) ;
- 조원일 (한국과학기술연구원 화공연구부) ;
- 조병원 (한국과학기술연구원 화공연구부) ;
- 윤경석 (한국과학기술연구원 화공연구부) ;
- 신치범 (아주대학교 화학공학과)
- Received : 1993.06.07
- Accepted : 1993.08.21
- Published : 1994.02.01
Abstract
A study on the iron electrode which is a good material for alkaline battery because of its superior characteristics including high theoretical capacity density, low toxicity, low cost and inexhaustible supply was performed to develop high performance nickel-iron secondary battery. The characteristics of chrage-discharge reaction were examined by cyclic voltammetry technique SEM and XRD analysis. The capacity of the test electrodes was determined by the costant current charge-discharge method. It was found that the purity and particle size of iron material were the major determinant factors of electrode capacity. With the addition of
고성능 니켈-철 축전지를 개발하기 위하여 알칼리 축전지로 이론적 용량밀도가 높고 저공해성, 저렴한 가격, 자원의 풍부성 등의 우수한 장점을 가지고 있는 철전극에 대한 연구를 수행하였다. 충방전반응의 특성을 전위주사법, SEM, XRD 분석으로 조사하였으며, 또한 전극용량을 정전류 충방전시험법으로 조사하였다. 철의 순도와 입자크기가 전극용량에 크게 영향을 미쳤으며, 첨가제
Keywords