Fluidization and Heat Transfer Characteristics in the Fluidized Bed(II)

기일고류동층내류동화(氣一固流動層內流動化) 및 전열특성(傳熱特性)에 관한 연구(硏究)(II)

  • Published : 1994.09.30

Abstract

The fluidization characteristics of the furan foundry sand fluidized bed and the heat transfer characteristics on a single spiral coil tube in the bed have been investigated. In the paper, the heat transfer coefficients for a single spiral coil tube are measured in the furan foundry sand bed as a function of the ratio of heated coil tube pitch to diameter(p/Do) and the ratio of heated coil tube pitch to particle size(p/dp). The experimental results are as follows. 1) Mean heat transfer coefficients increases according to the increasing ratio of heated coil tube pitch to diameter(p/Do). 2) The Increasing rates of mean Nusselt numbers are more greater in the case of p/Do=1.58 than p/Do=4.75. 3) Mean Nusselt number can be expressed by the following equation, $Nu_{mean}=C\;Re^m\;Pr_g^{0.4}(p/dp)^n$.

본 연구에서는 Furan foundry sand 유동층에서 유동화 특성과 Single spiral coil tube에 대한 열전달 특성을 실험하였으며, 전열관의 Pitch와 직경의 비(p/Do=1.58, 2.37, 3.17, 4.75) 및 전열관의 Pitch와 유동입자 크기의 비(p/dp=21.25, 25.15, 30.18, 35.93)가 전열특성에 미치는 영향을 실험적으로 연구하였다. 그 결과 다음과 같은 결론을 얻었다. 1) p/Do가 증가 할수록 평균 열전달계수는 증가한다. 2) 평균 Nusselt수의 증가율은 p/Do=4.75일 때보다 1.58 일 때가 더 크다. 3) 평균 Nusselt수와 Re수, $Pr_g$수 및 p/dp의 상관 관계식은 다음과 같이 나타낼 수 있었다. $Nu_{mean}=C\;Re^m\;Pr_g^{0.4}(p/dp)^n$.