Abstract

A survey was made on detection limit, reproducibility, matrix effect, linear dynamic range and the memory effect of yttrium and europium in order to analyze rare earth elements which exist as impurities in the rare earth oxide which is raw materials of fluorescent substance. When analysing a certain amount of thulium quantitatively using inductively coupled plasma mass spectrometry, it was found that the analysis was interfered with $EuO^+$ which is one of polyatomic ions caused by plasma. As the intensity of thulium linearly proportional to the europium concentration, it was possible to the determine the actual concentration of thulium.

형광체의 원료로 사용되고 있는 희토 산화물 중 불순물로 존재하는 희토류 원소를 분석하기 위하여 검출한계, 재현성, matrix effect, linear dynamic range 및 yttrium과 europium의 memory effect를 조사하였다. 유도결합 플라즈마 질량분석법(ICP-MS)에 의해 thulium의 정량분석시 europium이 존재함으로써 플라즈마 내에 polyatomic ion인 $EuO^+$이 형성되고, 이로 인해 thulium에 영향을 끼침을 확인할 수 있었다. Europium의 농도에 따른 thulium의 세기가 직선적으로 변화함을 이용하여 thulium의 실제 농도를 결정할 수 있었다.