Abstract
This study was conducted to investigate antigenic potential of DA-3030, a recombinant human granulocyte-colony stimulating factor, in guinea pigs and mice. In the active systemic anaphylaxis test, the guinea pigs sensitized with 1.25 or 12.5 $\mu\textrm{g}$/head of DA-3030 alone did not show any anaphylactic reaction. In the homologous passive cutaneous anaphylaxis reaction, anti-DA-3030 antibody was not detected in guinea pigs sensitized with 1.25 or 12.5 $\mu\textrm{g}$/head of DA-3030 alone. On the other hand, the guinea pigs sensitized with 12.5 $\mu\textrm{g}$/heed of DA-3030 incorporated in Freund's complete adjuvant(FCA) or 1 mg/head of ovalbumin incorporated in FCA showed anaphylactic reaction. Anti-DA-3030 antibody was also detected in those guinea pigs. In immunodiffusion test using the sera sensitized with DA-3030 incorporated in FCA, precipitating antibodies were detected only in the sera sensitized with DA-3030 or DA-3030 incorporated in FCA showed. In 24-hour heterologous PCA reaction with sera of C57BL/6 mice immunized with 1.25 or 12.5 $\mu\textrm{g}$/head of DA-3030 alone, none of the sera showed positive reaction. But sera of the animals immunized with 12.5 $\mu\textrm{g}$/head of DA-3030 incorporated in aluminum hydroxide gel(Alum) or 5 $\mu\textrm{g}$/head of ovalbumin incorporated in alum showed positive PCA reaction. DA-3030 did not cause anaphylactic shock or passive cutaneous anaphylaxis in guinea pigs and mice when given alone although DA-3030 incorporated in FCA or Alum induced anaphylactic shock and passive cutaneous anaphylaxis. From these results, it may be concluded the DA-3030 does not induce systemic allergic reaction when administered alone in its clinical use.