2단 평행판 전기집진기의 방전부 특성 실험

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner

  • 김익생 (한국기계연구원 공조기기실) ;
  • 이재옥 (한국기계연구원 공조기기실) ;
  • 김용진 (한국기계연구원 공조기기실) ;
  • 최헌오 (한국기계연구원 공조기기실)
  • 발행 : 1993.02.01

초록

The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.