Abstract
Spectrophotometric determination of cobalt by flow injection method is described. 2-(5-Bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino) aniline rapidly forms a water-soluble complex with cobalt in $NH_3-NH_4Cl$ buffer solution at pH 10.5. The absorption maxima of this complex is at 545 nm with molar absorptivity of $58000L\;mol^{-1}\;cm^{-1}$. The calibration curve of cobalt is linear over the range of 0.1 to 0.6ppm and the detection limit is 25ppb. The relative standard deviation is ${\pm}0.72%$ for 0.5ppm and the sampling rate is $60samples\;hr^{-1}$. The interfering effect of some cations and anions was investigated. Ni(II), Cu(II), Fe(III) and $CN^-$ interfered severely. The interfering effect of these matallic ions could be decreased by adding $1.0{\times}10^{-3}M$ EDTA solution to the carrier stream.
흐름주입법에 의하여 분광광도 방법으로 코발트를 정량하였다. $NH_3-NH_4Cl$ 완충용액(pH 10.5)에서 2-(5-bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)aniline은 코발트와 수용성 착물을 형성한다. 이 착물의 최대흡수 파장은 545nm이고, 몰흡광계수는 $58000L\;mol^{-1}\;cm^{-1}$이다. 코발트의 검정곡선은 0.1~0.6ppm 범위에서 직선관계를 보였고, 검출한계는 25ppb였다. 상대표준편차는 0.5ppm에 대하여 ${\pm}0.72%$였고, 시료의 채취속도는 $60samples\;hr^{-1}$였다. 여러 가지 양이온과 음이온의 방해효과를 조사한 결과, NI(II), Cu(II), Fe(III) 및 $CN^-$이 많은 방해를 하였다. 그러나 운반체흐름에 $1.0{\times}10^{-3}M$ EDTA 용액을 넣음으로써 금속이온들의 방해를 감소시킬 수 있었다.