Evaluation of Total Loss of Feedwater Accident/Recovery Phase and Investigation of the Associated EOP

완전급수상실사고/복구과정의 평가와 관련비상운전절차의 검토

  • Published : 1993.03.01

Abstract

To evaluate the sequence of event and the Thermohydraulic behavior during total loss of feedwater accident and recovery procedure, a RELAP5/MOD3 calculation is performed and compared with the LOFT L9-l/L3-3 experiment. Also, the predictability of the code for the major Thermohydraulic phenomena following the accident is assessed. As a result, it is found that a pressure control using the spray until the time the water level reaches the top of the pressurizer, an overpressure protection by pressurizer PORV, a recovery of the secondary heat removal capability by refilling steam generator, and an effective cooldown by the continued natural circulation can be performed without core uncovery. It is also found that the plant-specific evaluation is necessary to confirm the effectiveness of the current symptom-oriented emergency operating procedure, especially in an overpressure protection performance and steam generator recovery performance.

완전급수상실사고 및 복구가정의 사고전개와 열수력학적 거동을 평가하기 위해 RELAP5/MOD3 계산을 수행하고 LOFT L9-l/L3-3 실험 결과와 비교하였다. 또한 본 사고의 주요 열수력 현상에 대한 코드의 예측도를 평가하였다. 본 연구의 결과로서 가압기 수위가 만수위에 도달할 때까지 살수를 이용한 압력 제어, 가압기 압력방출 밸브를 통한 가압방지, 증기발생기 재충수에 의한 이차측 열제거 능력의 재확보, 지속적인 자연순환에 의한 효과적인 일차계통의 냉각등이 이루어 질 수 있고 이 과정중 노심노출은 나타나지 않음이 밝혀졌다. 또한 현재의 현상-중심 비상운전절차서 특히 과압방지성능 및 증기발생기 회복절차 등의 유효성을 입증하기 위해서는 발전소 고유한 평가가 필요함이 밝혀졌다.