연소장치를 이용한 소형 전기집진장치의 집진 효율에 관한 연구

A Study on Collection Efficiency of Pilot Electrostatic Precipitator

  • 한재균 (동아대학교 대학원 환경공학과) ;
  • 최금찬 (동아대학교 환경공학과)
  • 발행 : 1993.06.01

초록

Electrostatic Precipitator has been widely used to get high efficiency which is required for collection of fine particles. In order to provide collection efficiency and size distribution data for a pilot electrostatic precipitator, a pilot study has been conducted on fly ash from pulverized coal burning apparatus. The aims of this study are to investigate characteristics of electric charge, to measure collection efficiency varied with the applied voltage, to get an optimum current and current density. Optimum current density was obtained to 0.7mA/$cm^2$ at the average electric field strength 2.33kV/cm in this experiment. Maximum particle collection efficiency was indicated 99.21% at the applied voltage 7kV. Finally, particle size distribution is also compared with photographic results. Both coarse and fine particles at the range of 0.5$\sim$2$\mu$m and 3$\sim$10 SEM $\mu$m were clearly removed by increasing applied voltage.

키워드

참고문헌

  1. 전기학회논문지 v.33 no.6 디-젤배진용 전기집진장치의 성능향상을 위한 강력 전치하전장치의 개발 문재덕
  2. 동아대학교산업대학원 공학석사 학위논문 Diesel 자동차 배출입자의 배출특성 및 성상에 관한 연구 조정구
  3. J. Air Poll. Cont. Assoc. v.38 no.11 ESP Performance with Atmospheric Fluidized-Bed Combustion Altman Ralph F.
  4. Operational Resistivity Measurements on Freshly Generated Fly-Ashes Goard,P.R.C.(et al.)
  5. J. Air Waste Manage. Assoc. v.40 no.11 Calculation of Electric Field Strength Distributions for New Electrostatic Precipitator Discharge Electrode Designs Hao,J.;K.He;H.Chao
  6. J. Air Poll. Cont. Assoc. v.30 no.1 Factors Affecting Resistivity in Electrostatic Precipitation Katz,J.
  7. CSIRO Conference on Electrostatic Precipitation, Paper No. 5 Effect of gas composition on sparking characteristics of back discharge Masuda,S.