Abstract
Ground-water temperature is one of the parameters for observing diarges in the state of the ground-water regime in time and space, which relate to conditions for recharge as well as the influence of various natural and man-induced fadors on the regime. Because ground-water satura tes much of the rock materiats in the upper layer of the earth's csust the water temperature reflects in part the temperature of the water-bearing rocks. The mobffity and thennal capadty of groud-waters, however, serves to redistribute some of the heat within the stratosphere and to influence the developement of the geothermal regime within this sphere. The utilization of temperature data of the study area(25 points) in the solution of hydrogeologic problems requires an understanding of some of the fundamental aspects of subsurtice temperatures. These include the depth of penetration of heat waves generated of the surtace, the rate of propagation of the waves, and the geothermal gradient in the study area of Taegu.
지하수의 온도측정자료는 자연상태 및 인공적인 충진(Recharge)에 의한 지하수의 유동상태 및 대수층의 특성을 파악할 수 있는 중요한 parameter가 된다. 대수층내 지하수의 온도는 지하수를 저류하고 있는 대수층의 구성암석들의 온도를 반영하며, 지하수의 유동성과 저온능력은 지각내부에서 발달된 지열을 대수층내 분산시키는 역할을 한다. 조사지역내(25개 시추공)에서 측정된 지하수온도자료들은 대수층내 온도분포의 근원적인 수리지질학적 의미와 수리역학적 문제점 해결에 유용하게 이용되며, 또한 지표변으로부터 열원이 전달되는 전파율과 심부 증온율 연구에 기여된다.
Keywords